PREDATOR 61169 OWNER'S MANUAL Pdf Download (2024)

PREDATOR 61169 OWNER'S MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. Predator Manuals
  4. Portable Generator
  5. 61169
  6. Owner's manual

2500 watt inverter generator

Hide thumbs

1
Table Of Contents 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
  • Contents
  • Table of Contents
  • Troubleshooting
  • Bookmarks

Table of Contents

  • Table of Contents

  • Specifications
  • Symbol Definitions

  • Safety

    • Specifications

    • Service Precautions

    • Save These Instructions

  • Setup

  • Operation

    • Manual Start

    • Starting the Engine

    • Nominal 12VDC Output

    • Generator

    • Engine Oil

    • Generator

  • Generator

    • Cleaning/Maintenance/Lubrication Schedule

    • Generator

  • Engine Oil

  • Spark Plug
  • Valve Clearance

  • Maintenance
    • Generator

    • Checking and Filling Fuel

    • Engine Oil Change

  • Troubleshooting
  • Parts Lists and Diagrams
    • Parts Lists and Diagrams

    • Wiring Diagram

  • Warranties

Advertisem*nt

Quick Links

  • 1 Specifications
  • 2 Maintenance
  • 3 Spark Plug
  • 4 Troubleshooting
  • 5 Parts Lists and Diagrams
  • 6 Parts Lists and Diagrams
  • Download this manual

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

PREDATOR 61169 OWNER'S MANUAL Pdf Download (2)

Related Manuals for Predator 61169

  • 5500/6500 watt portable generator (25 pages)

  • 3200 rated watts 4000 max watts (25 pages)

  • 7000 rated watts 8750 max watts (25 pages)

  • Portable Generator Predator 68525 Owner's Manual

    8750 watt portable generator (24 pages)

  • 7000 running watts/ 8750 peak watts portable generator (25 pages)

  • Portable Generator Predator 68525 Quick Start Manual

    (4 pages)

  • Portable Generator Predator 68525 Quick Start Manual

    (4 pages)

  • Portable Generator Predator 69728 Owner's Manual

    4000 watt portable generator (24 pages)

  • 3200/4000 watt (24 pages)

  • 13,500 watt portable generator (32 pages)

  • Portable Generator Predator 5500 Quick Start Manual

    (4 pages)

  • Portable Generator Predator 5500 Quick Start Manual

    (4 pages)

  • Portable Generator Predator 69672 Quick Start Manual

    (2 pages)

  • 4000 watt (28 pages)

  • 13500 watts (36 pages)

  • Predator 4375 Watt Portable Generator Manual

    (article)

Summary of Contents for Predator 61169

  • Page 2: Table Of Contents

    The emissions control system for this Engine is warranted for standards set by the U.S. Environmental Protection Agency. For warranty information, refer to the last pages of this manual. Page 2 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 3: Safety

    It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. SAVE THESE INSTRUCTIONS ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 3...
  • Page 4: Specifications

    Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. Page 4 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 5 12. Do not exceed the maximum power rating of the 27. Use only accessories that are recommended generator. Make sure that the total electrical rating by Harbor Freight Tools for your model. of the all of the tools or appliances plugged into Accessories that may be suitable for one...
  • Page 6: Service Precautions

    6. Maintain labels and nameplates on the equipment. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement. SAVE THESE INSTRUCTIONS. Page 6 For generator technical questions, please call 1-800-444-3353.
  • Page 7: Setup

    12VDC Receptacle Overload Oil Alert 120V~ Receptacles Choke Ground Starter Terminal Handle Exhaust Air Filter and Oil Fill Fuel Access panel Valve ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 7 For engine technical questions, please call 1-800-520-0882.
  • Page 8: Operation

    Note: Do not use gasoline containing more than while the smell of fuel hangs in the air. 10% ethanol (E10). Do not use E85 ethanol. Page 8 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 9: Manual Start

    Repeat until the Engine starts. Note: Do not let the Starter Handle snap back against the housing. Hold it as it recoils so it doesn't hit the housing. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 9...
  • Page 10: Nominal 12Vdc Output

    4. If this 12VDC circuit protection is tripped, Negative Terminal reduce the load, and press the red Reset Button next to the outlet. Reset Button Page 10 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 11: Generator

    Generator ventilation away. 4. Restart Generator (the OVERLOAD device will automatically reset), and reconnect devices while being careful to not overload Generator. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 11 For engine technical questions, please call 1-800-520-0882.
  • Page 12: Generator

    3. Close the Fuel Valve. NOTICE Drain fuel at end of season or warranty is void. See Storage on page 16 for complete storage instructions. Page 12 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 13: Maintenance

    Replace fuel line if necessary Service more frequently when used in dusty areas. These items should be serviced by a qualified technician. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 13 For engine technical questions, please call 1-800-520-0882.
  • Page 14: Generator

    Access Panel. Full level NOTICE: Do not run the engine with too little oil. The engine will be permanently damaged. Page 14 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 15 If the electrode has deposits on it, polish it using emery paper. If the white insulator is cracked or 8. Replace Access Panel. chipped, the spark plug needs to be replaced. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 15 For engine technical questions, please call 1-800-520-0882.
  • Page 16 Tighten securely. fuel stabilizer’s recommended time period, or if the engine does not start. Page 16 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 17: Troubleshooting

    4. Have qualified technician adjust/ mis-adjusted or stuck. repair valves and tappets. Follow all safety precautions whenever diagnosing or servicing the generator or engine. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 17 For engine technical questions, please call 1-800-520-0882.
  • Page 18 Follow all safety precautions whenever diagnosing or servicing the generator or engine. Page 18 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 19: Parts Lists And Diagrams

    Piston Spacer Ring Spacer Rails Second Piston Ring Top Piston Ring Semicircle Key Note: When ordering parts from this diagram add a -b suffix. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 19 For engine technical questions, please call 1-800-520-0882.
  • Page 20 Check Plate Valve Rocker Intake Valve Spring Rocker Intake Valve Rocker Shaft Note: When ordering parts from this diagram add a -d suffix. Page 20 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 21: Parts Lists And Diagrams

    Rubber Tube Rubber Tube Rubber Tube Oil Separator Asm. Spacer Carburetor Asm. Note: When ordering parts from this diagram add a -f suffix. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 21 For engine technical questions, please call 1-800-520-0882.
  • Page 22 Gasket Elbow Nut M6 Gasket Muffler Asm. Bolt M6×80 Bolt M6×50 Note: When ordering parts from this diagram add a -h suffix. Page 22 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 23 Fuel Hose Fuel Filter Asm. Fuel Hose Fuel Hose Dump Valve Tube Note: When ordering parts from this diagram add a -j suffix. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 23 For engine technical questions, please call 1-800-520-0882.
  • Page 24 Bolt M4×16 Bolt M4×10 Bolt M4×6 Stepper Motor Asm. Governor Spring Note: When ordering parts from this diagram add a -m suffix. Page 24 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 25 AC Outlet Engine Switch Panel Asm. DC Outlet Screw M4×12 Nut M5 Note: When ordering parts from this diagram add a -p suffix. ITEM 61169 For generator technical questions, please call 1-800-444-3353. Page 25 For engine technical questions, please call 1-800-520-0882.
  • Page 26: Wiring Diagram

    Note: If product has no serial number, individually as replacement parts. record month and year of purchase instead. Page 26 For generator technical questions, please call 1-800-444-3353. ITEM 61169 For engine technical questions, please call 1-800-520-0882.
  • Page 27: Warranties

    Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.
  • Page 28 Harbor Freight Tools Emissions Control Service and Maintenance Defects Warranty provisions Component parts which are not scheduled for replacement as required maintenance or are scheduled only for regular inspection Length of Coverage to the effect of “repair or replace as necessary” are warranted for HFT warrants to a first retail purchaser and each the warranty period.
PREDATOR 61169 OWNER'S MANUAL Pdf Download (2024)

FAQs

Does a predator Generator need to be grounded? ›

The Generator must be earth-grounded in accordance with all relevant electrical codes and standards before operation. using a generator indoors can KiLL yOu in MinutES.

What kind of oil does a 6500 predator Generator take? ›

Engine Oil Type SAE 10W-30 Capacity 20 fl. oz. Run Time @ 25% Load with full tank 11 hr.

What kind of oil does a predator 5000w take? ›

Engine oil capacity is 0.64 qt. For general, all-temperature use, SAE 10W-30 is recommended.

What happens if you don't ground a generator? ›

Failure to ground a generator is hazardous and can lead to: Electrical overload on your generator which can damage the wiring or other sensitive parts of the electrical system, unless your generator has overload protection like all the generators at DuroMax. Electrocution from touching ungrounded metal.

Do I really need a grounding rod for generator? ›

If the portable generator is providing electric power to a structure by connection via a transfer switch to a structure (home, office, shop, trailer, or similar) it must be connected to a grounding electrode system, such as a driven ground rod.

Can I use 5W30 instead of 10W30 in my generator? ›

Most likely. Almost anything can. But, if it's a hot running air cooled engine, and you use it in the summer, a straight 30 oil would be better. If it's going to be used in the winter, you'll want a 5W-30 oil instead – this is especially important in our area in the winter months to ensure easy & reliable starting.

What is the difference between SAE 30 and 10W30 for generator? ›

During colder weather, it is better to use a 10W30 motor oil rather than the SAE30. SAE 30 Motor Oil is better during warmer temperatures. In this case, I would use 10W30. It is suitable year around, unless temperatures are extremely low.

What weight oil goes in a predator generator? ›

Engine Oil Type SAE 10W-30 Capacity 37 fl. oz.

What will a 6500 running watt generator run? ›

If you are living in a region that often faces power cuts, then you definitely need a power generator like a 6500-watt home generator. You can run lights, kitchen appliances, and even AC and fan.

Do generators take synthetic oil? ›

Synthetic oils have a higher viscosity index, provide energy efficiency, and improve generator maintenance. They are also more stable than mineral oils, which is immensely important in extreme working conditions.

What oil do you break in a generator? ›

Make sure you are using regular 10W-30 or full synthetic 5W-30 if extreme cold weather condition. After the first 25 hours, you will have to change the oil every 100 hours. Also, another tip you could remember, to check the oil level, don't forget to dip the dipstick in and don't screw it in.

How much oil does a predator engine need? ›

Engine Oil Type SAE 10W-30 above 32° F 5W30 at 32° F or below Capacity 0.5 Quart Run Time @ 50% Load with full tank 3 hr. The emissions control system for this Engine is warranted for standards set by the U.S. Environmental Protection Agency.

What 4 stroke oil do I use for a generator? ›

PowerFit 4L SAE30 4-stroke oil is ideal for your mower, generator or pressure washer.

What kind of oil does a 4000 watt champion generator take? ›

Champion also makes it easy to monitor voltage, frequency and operating hours with Intelligauge. Designed for safety with convenient push-to-reset circuit breakers, a low oil shut-off sensor plus an included oil funnel for easy changes, this unit has a 0.5-quart oil capacity (recommended 10W-30).

Do you need to ground a generator if you use an extension cord? ›

You do not need to ground the generator if you're solely using it with extension cords.

Does a permanent generator need to be grounded? ›

Key Takeaways of Grounding and Bonding Generators

Connect to the generator frame any conductor that must be grounded if the generator is a component of a separately derived system. The supply conductors of a permanently installed generator must include a conductor providing an effective ground-fault current path.

What is the best way to ground a portable generator? ›

Here's the key: The portable generator's grounding is achieved by connecting its grounding terminal to the grounding terminal in the main electrical panel. This connection establishes a solid and safe electrical bond between the generator and the existing grounded system of your home.

Does a generator need to be on level ground? ›

Place the Generator on Level Ground

A typical generator vibrates when it runs. If you place such a generator on uneven ground, the vibrations may displace the generator or even trip it over. That would be a danger because the generator should always run in its upright position to avoid fuel spillage.

References

Top Articles
Latest Posts
Article information

Author: Francesca Jacobs Ret

Last Updated:

Views: 6152

Rating: 4.8 / 5 (68 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Francesca Jacobs Ret

Birthday: 1996-12-09

Address: Apt. 141 1406 Mitch Summit, New Teganshire, UT 82655-0699

Phone: +2296092334654

Job: Technology Architect

Hobby: Snowboarding, Scouting, Foreign language learning, Dowsing, Baton twirling, Sculpting, Cabaret

Introduction: My name is Francesca Jacobs Ret, I am a innocent, super, beautiful, charming, lucky, gentle, clever person who loves writing and wants to share my knowledge and understanding with you.